Re: [TRNSYS-users] Not able to put custom input in Type 56 (Multi zone Building)



The way to do this is to make a different *.bui file for each iteration of the parametric table then add a series of ASSIGN statements in your *.dck so that each of the *.bui files is assigned a unique logical unit number. You then create an equation that sets the value of the logical unit number that Type56 will use and you replace Type56's logical unit parameter with the name of the defined variable. When you create the parametric table in TRNEdit, you'll select that same variable name and assign one table run to each of the logical unit values.

kind regards,

 David