Duygu,
You are correct that there is not a model of a PEM electrolyzer
in TRNSYS at the moment.
Are you working on modelling a specific PEM electrolyzer or a more general one? The reason I ask is that if you are working with a specific one, we could look at what information the manufacturer can provide and see if it would be possible to write a performance map component rather than a more first-principals model such as Type170.
kind regards,
David
Hi Trnsys-Users;
I have desingned project,including Pem fuel cell and pem electrolyzer. As an fuel cell i used Type 170f but as an electrolyzer i don't know what i will use. Trnsys has not pem electrolyzer. Should i add a component that contains the pem electrolyzer by writing fortran code?
King Regards
Duygu Kemeriz
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 3 North Pinckney Street - suite 202 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com