Maamar,
That is correct; Type204 is compiled as a 32-bit DLL and needs to be recompiled as a 64-bit DLL if you are going to use it with Trnsys18. You may be able to use the TypeStudio to do the recompiling.
kind regards,
 David
Dear users,
I am planning to use Type 204 (Phase change material) from TRNSYS 16 to TRNSYS 18
but I cant' be opened correctly in TRNSYS18
TRNSYS Message 105 : A TYPE was called in the TRNSYS input file butwas either not linked into trndll.dll or was not found in an external dll.A dummy subroutine was called in its place. Please link the TYPE or removeit from the input file** Reported information : Type204 could not be located in either thetrndll.dll or in an external dll. Please relink theTRNDll.dll includingthis Type or make sure that an external DLL in the \UserLib\DebugDLLs and\UserLib\ReleaseDLLs folders contain the Type
what can I do please?
Thanks
 maamar
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 3 North Pinckney Street - suite 202 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com