I have posted some pre-release versions of Type98 and ContamX 3.2.0.3 on the NIST Multizone Modeling website.
These versions previously resided on the CONTAM Yahoo Group which no longer allows for uploaded content.
Download the zip file that includes ContamX 3.2.0.3 and Type 98 for the 32 bit versions of TRNSYS provided on this page.

https://www.nist.gov/el/energy-and-environment-division-73200/nist-multizone-modeling/software-tools/type98

There is a readme file that provides instructions on how to utilize the files contained in the zip file.

- Stuart

 

 

From: Obaid <obaidullahya@gmail.com>
Sent: Thursday, February 6, 2020 4:21 AM
To: Dols, William Stuart (Fed) <william.dols@nist.gov>
Cc: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Subject: Re: [TRNSYS-users] Contam+Trnsys coupling

 

Hi, 

It is 32 bit installed on a 64bit Windows 10.

thanks, 

Obaid,   

 

On Wed, Feb 5, 2020 at 9:35 PM Dols, William Stuart (Fed) <william.dols@nist.gov> wrote:

Are you using a 32 bit or 64 bit version of TRNSYS 17?

- Stuart

 

 

From: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> On Behalf Of Obaid via TRNSYS-users
Sent: Wednesday, February 5, 2020 9:36 AM
To: trnsys-users@lists.onebuilding.org
Cc: Obaid <obaidullahya@gmail.com>
Subject: [TRNSYS-users] Contam+Trnsys coupling

 

Hello,

I created a coupled project with Contam 3.2 and Trnsys 17 but when I run the simulation, it shows this error that may or may not have originated from the model.

message: ((The project path given is longer than the allowed 260 characters by Windows))

Though it says that the length of path for the current project exceeds the maximum limit but it Doesn't.

I also enabled the filesytem's LongPathsEnabled but the error persists.

The files show the same error in another computer too.

What else should I do? 

Regards,

Obaid