Salma, There are (as usual) a number of different ways of having all
the results from a parametric run put into the same output file.
One way is to use a Type25 printer as an output device in your
simulation and to set it to "append" mode instead of "overwrite
mode." The mode is controlled by a parameter. The other thing
you'll need to do is to make sure that the name of the output file
is NOT the same as the name of your input file, otherwise there
will be one output file produced per table run. Note that a number
of the standard printer output components in TRNSYS allow the
switch between append and overwrite mode. kind regards, David