Re: [TRNSYS-users] DQAIRdt & QTRANS



Dear Arne,
please update to TRNSYS 18 to access all Balance variables as NTypes directly.

Best
Jakob

__________________________________________________________________________________________________

 

Transsolar Energietechnik GmbH

Curiestraße 2

70563 Stuttgart

http://www.transsolar.com

Transsolar: KlimaEngineering- Technologien für energieeffizientes Bauen und Nutzerkomfort in Gebäuden

Stuttgart – München – New York – Paris

Geschäftsführer :Diplom-Ingenieur Matthias Schuler, Diplom-Ingenieur Thomas Auer, Diplom-Physiker Stefan Holst, Diplom-Betriebswirt Dieter Schnelle

Eingetragen beim Amtsgericht Stuttgart HRB 23347,

Steuernummer: 99073/00911,USt-IdNr.: DE 152272639

 

The simulation project you have sent will be stored on the local servers of Transsolar Energietechnik GmbH for the duration of the project support. Our employees are obliged by us to confidentiality. After this period, all project-related data is deleted.

 

The storage of your personal e-mail and other contact information is based on the mutual interest in the execution of this traffic and on a mutual business contact. If you have any questions, please contact our data protection officer at privacy@transsolar.com. Our privacy policy can be found here.


Von: Arne Hübner <arne.nils.huebner@gmail.com>
Gesendet: Montag, 2. September 2019 16:06
An: hotline <hotline@Transsolar.com>
Betreff: AW: [TRNSYS-users] DQAIRdt & QTRANS
 

I have Version 16 I think. Maybe that is the Problem.

 

Gesendet von Mail für Windows 10

 

Von: hotline
Gesendet: Montag, 2. September 2019 15:06
An: TRNSYS users mailing list at OneBuilding.org
Cc: Arne Hübner
Betreff: AW: [TRNSYS-users] DQAIRdt & QTRANS

 

Hi Arne,

 

weird - could you send me these files from your installation:

  • <TRNSYS-Installation>\user18.id
  • <TRNSYS-Installation>\trnsys.ini
  • <TRNSYS-Installation>\Building\Trnbuild.ini

Best
Jakob

 

__________________________________________________________________________________________________

 

Transsolar Energietechnik GmbH

Curiestraße 2

70563 Stuttgart

http://www.transsolar.com

Transsolar: KlimaEngineering- Technologien für energieeffizientes Bauen und Nutzerkomfort in Gebäuden

Stuttgart – München – New York – Paris

Geschäftsführer :Diplom-Ingenieur Matthias Schuler, Diplom-Ingenieur Thomas Auer, Diplom-Physiker Stefan Holst, Diplom-Betriebswirt Dieter Schnelle

Eingetragen beim Amtsgericht Stuttgart HRB 23347,

Steuernummer: 99073/00911,USt-IdNr.: DE 152272639

 

The simulation project you have sent will be stored on the local servers of Transsolar Energietechnik GmbH for the duration of the project support. Our employees are obliged by us to confidentiality. After this period, all project-related data is deleted.

 

The storage of your personal e-mail and other contact information is based on the mutual interest in the execution of this traffic and on a mutual business contact. If you have any questions, please contact our data protection officer at privacy@transsolar.com. Our privacy policy can be found here.

Von: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> im Auftrag von Arne Hübner via TRNSYS-users <trnsys-users@lists.onebuilding.org>
Gesendet: Montag, 2. September 2019 14:57
An: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Cc: Arne Hübner <arne.nils.huebner@gmail.com>
Betreff: Re: [TRNSYS-users] DQAIRdt & QTRANS

 

Hey Jakob,

 

but when I click on „balances“ I cant see These NTypes. I just see the 8 different NTypes for the balances. Look at the Picture.

 

Best

 

Arne

 

Gesendet von Mail für Windows 10

 

Von: hotline via TRNSYS-users
Gesendet: Montag, 2. September 2019 14:41
An: TRNSYS users mailing list at OneBuilding.org
Cc: hotline
Betreff: Re: [TRNSYS-users] DQAIRdt & QTRANS

 

Dear Arne,

 

all Balance Outputs are accessible as NTypes, too.

In TRNBuild, go to the Outputs Menu and choose balances:

 B4_dQair   > NType 951

 B4_Qtrans > NType 957

 

Best
Jakob Merk

 

 

__________________________________________________________________________________________________

 

Transsolar Energietechnik GmbH

Curiestraße 2

70563 Stuttgart

http://www.transsolar.com

Transsolar: KlimaEngineering- Technologien für energieeffizientes Bauen und Nutzerkomfort in Gebäuden

Stuttgart – München – New York – Paris

Geschäftsführer :Diplom-Ingenieur Matthias Schuler, Diplom-Ingenieur Thomas Auer, Diplom-Physiker Stefan Holst, Diplom-Betriebswirt Dieter Schnelle

Eingetragen beim Amtsgericht Stuttgart HRB 23347,

Steuernummer: 99073/00911,USt-IdNr.: DE 152272639

 

The simulation project you have sent will be stored on the local servers of Transsolar Energietechnik GmbH for the duration of the project support. Our employees are obliged by us to confidentiality. After this period, all project-related data is deleted.

 

The storage of your personal e-mail and other contact information is based on the mutual interest in the execution of this traffic and on a mutual business contact. If you have any questions, please contact our data protection officer at privacy@transsolar.com. Our privacy policy can be found here.

Von: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> im Auftrag von Arne Hübner via TRNSYS-users <trnsys-users@lists.onebuilding.org>
Gesendet: Montag, 2. September 2019 10:25
An: trnsys-users@lists.onebuilding.org <trnsys-users@lists.onebuilding.org>
Cc: Arne Hübner <arne.nils.huebner@gmail.com>
Betreff: [TRNSYS-users] DQAIRdt & QTRANS

 

Hello TRNSYS-Users,

I choosed Energy balance 4 as my balance Output for my multizone Building. Now i want to use Type 28 for a detailed overview of my losses and gains. I have issues to find the Right Output in Type 56 for „DQAIRdt“ and „QTRANS“. When is use NType 8 for DQAIR and NTYPE 27 for QTRANS I have not the same results like in my Energy balance 4. Does anyone know which Output I have to use?

Thank you.

 

Regards,

 

Arne

 

Gesendet von Mail für Windows 10