Jibi, I suspect that you may have more than one online plotter that
are pointed to the same output file. Check the "external files"
tab of all your online plotters and make sure that each of them
has a different filename. The *** syntax indicates that TRNSYS should use the name of your
Simulation Studio project for the name of the file. For instance
if your project is called project1.tpf and a plotter's external
files is ***.plt then the output file will be called project1.plt.
If two online plotters are both set to ***.plt then both will
write to the same output file. Whatever file name you give, TRNSYS will always write a text file. You might use something like ***(1).plt, ***(2).plt, etc. for the onlines' external files. kind regards, David