Dear users, I am finding that energy balance issues with type 362. I find that the energy balance does not sum zero in some conditions, I have tooled around finding that the following conditions cause the error> ·
Variable supply temperature. ·
Step signal on mass flow control signal (flow goes from 0 to full), the energy balance fails on first time steps after “ON” signal or first time steps after “OFF”. I feel there is a convergence problem that does not appear on the list file. Supporting this, I tried changing the “convergence tolerance”, finding less errors on the energy balance increasing it (from default 0.0001
to 0.001). I am using type362 in trnsys17 project with a simple room modelled with type 56. Has anyone experienced this problem? How can it be solved? Regards, Joaquim Romaní