Multiply the two signals together in an equation and feed that to the pump. The on/off part should be either 0 or 1 when you multiply it by the function for the mass flow rate.
Jeff
---
Jeff Thornton President - TESS LLC 3 N. Pinckney Street, Suite 202, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com
On 04/15/2019 7:55 am, MEHMOOD Sajid via TRNSYS-users wrote:
Hi Dear All,I have a question regarding control signal. I am using Type-110 (Variable speed pump). i want to give two signal to pump. one for to control mass flow rate and second as to set pump on/off schedule. is it possible to give two signal?If yes, please guide me.Thank you.Best Regards,SajidThe University of Edinburgh is a charitable body, registered in Scotland, with registration number SC005336.