[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] type47 charging time



Hello

I try to reproduce the charge  and discharge of a battery  given in Example 8.10.1 of Duffie Beckman book using type 47c and I find a charging time which is 6 times shorter than what they get. I guess the reason why is that the integration in time of the current is the total capacity in Duffie Beclkamn’s book and it is the capacity of one cell in TRNSYS type 47. Is it possible to know which solution is better since the current in one cell is the cell as the total current of the battery ?

Thank you very much

Louis lamarche

Attachment: exemple_batterie.tpf