[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Thermal storage tank



Thanks,

Arrate

Jeff Thornton via TRNSYS-users <trnsys-users@lists.onebuilding.org> escribió:

534 requires that you have matched inlets and outlets but it’s easy to mimic un-matched ports by using a simple mixing valve. If you have three inlets and two outlets in reality, you just set it up as 3 and 3 in 534 and mix the two together that are leaving from the same location,

Jeff

Sent from my iPhone

On Mar 7, 2019, at 4:51 AM, Hamidreza Esfehani via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:

You can define different number of inlet and outlets ports which I think is what you are looking for.

-----Ursprüngliche Nachricht-----
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] Im Auftrag von ARRATE HERNANDEZ via TRNSYS-users
Gesendet: Donnerstag, 7. März 2019 11:29
An: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Cc: ARRATE HERNANDEZ <arrate.hernandez@ehu.eus>
Betreff: Re: [TRNSYS-users] Thermal storage tank

Thanks a million. And is there any type that allows to define different number of inputs and outputs?

Hamidreza Esfehani via TRNSYS-users
<trnsys-users@lists.onebuilding.org> escribió:

Dear Arrate,

you can use Type 534 from Storage Tank Library (TESS).
There you can give the number of ports (paired input/output) that you need.

Best,
Hamid

Hamidreza Heidar Esfehani
Wissenschaftlicher Mitarbeiter|Research Associate

Leibniz Universität Hannover
IEK Abt.Gebäudetechnik
Herrenhäuser Str. 8
30419 Hannover

Telefon : +49 (0)511 762 3811
Fax : +49 (0)511 762 3016
hamidreza.esfehani@iek.uni-hannover.de

www.iek.uni-hannover.de/gebaeudetechnik
-----Ursprüngliche Nachricht-----
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org]
Im Auftrag von ARRATE HERNANDEZ via TRNSYS-users
Gesendet: Donnerstag, 7. März 2019 11:14
An: trnsys-users@lists.onebuilding.org
Cc: ARRATE HERNANDEZ <arrate.hernandez@ehu.eus>
Betreff: [TRNSYS-users] Thermal storage tank

Dear users,

I need a stratified cylinder storage tank with 3 inputs and 2 outputs
to my project. Any of you know how can I get it? Thanks,

Arrate


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org