It won’t be a very exciting plot because parameters don’t change with time, but if you still want to do it the easiest way is with equations.  Set an equation to the collector area, use that name when you specify the area in the parameters tab of the proforma, and then connect that equation to your plotter.

Jeff - TESS

Sent from my iPhone

On Feb 21, 2019, at 11:18 AM, Farhan Malik via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:

I want to ask you that can i plot on graph the parameters of any component in TRNSYS. There is option to plot output variables but there is no option to plot parameters.
Like i want to plot area of flat plate collector...

On Feb 15, 2019 3:02 AM, <trnsys-users-request@lists.onebuilding.org> wrote:
Send TRNSYS-users mailing list submissions to
        trnsys-users@lists.onebuilding.org

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

or, via email, send a message with subject or body 'help' to
        trnsys-users-request@lists.onebuilding.org

You can reach the person managing the list at
        trnsys-users-owner@lists.onebuilding.org

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

   1. Re: Type531->534 illegal param value error (Jeff Thornton)


---------- Forwarded message ----------
From: Jeff Thornton <thornton@tess-inc.com>
To: "TRNSYS users mailing list at OneBuilding.org" <trnsys-users@lists.onebuilding.org>
Cc: Le Talave <contact@letalave.com>
Bcc: 
Date: Thu, 14 Feb 2019 10:22:27 -0600
Subject: Re: [TRNSYS-users] Type531->534 illegal param value error
Olivier,

Did you use the plug-in to generate the data file or try to do it by hand?  The plug-in does all of the file formatting for you and is highly recommended!

Jeff - TESS

Sent from my iPhone

On Feb 14, 2019, at 3:35 AM, Le Talave via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:

Hello,

I'm trying to use the Tess lib Flat bottom Tank type 531. As specified in the documentation, I write all the parameters needed in the data file, but tnrsys returns a message 103, with an illegal parameter. The reference of this parameter is variable for the same simulation, so it seems that i can't use it to find the error. "Parameter 9" error often comes back. I tried many configurations, with no ports, no hx, no auxiliary, I carefully cycled the concerned parameters by repeating them in the file, but the problem is the same.

Is there a special syntax to use in the dat file? When the documentation says "no further parameter is needed", should I continue with the next used parameter or do I have to write something in the dat file before go the the next one? Is it possible to annotate the dat file (write a text that type531 doesn't "see"), so that I can give a name to each parameter and make faster modifications?

Thanks a lot for your help

Kind regards,

Olivier

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________