[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Fwd: Multizone coupling



Michele,

 

You should move both airnodes to one Zone.

 

  • Open the zone with the airnode you want to move
  • Move active airnode to your target zone
  • Now you have one zone with several airnodes

 

To define an airflow between these two zones, you can use Couple (05-Multizone docu)

 

 

Best,

Christoph

 

Von: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> Im Auftrag von Michele Vella via TRNSYS-users
Gesendet: Mittwoch, 13. Februar 2019 12:15
An: trnsys-users@lists.onebuilding.org
Cc: Michele Vella <michele.vella.15@um.edu.mt>
Betreff: [TRNSYS-users] Fwd: Multizone coupling

 

 

I have 2 zones on top each other but there is no ceiling touching them so i did the 2 touching surfaces as virtual surfaces.The problem is I dont know how to couple them together as when i heat the upper zone it is not effecting the temperature of the lower zone. When i press couple on the TRN build it just shows up the airnode window.

 

Regards

Michele Vella