Makram,

You can use equations to set the control card variables.  For example:

STARTSIM= 0
DAYS= 57
STOPSIM= STARTSIM+DAYS*24

Then use these names in the appropriate spots in the control cards.  The only caveat is that they can’t change during the simulation.

Jeff / TESS

Sent from my iPhone

On Jan 9, 2019, at 2:39 AM, Makram ABDELLATIF via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:

Hello everyone,

 

Is there a way to change control cards automatically?

For example, by creating a parametr (or equation) or by calling a variable from an external txt file.

Thank you.

 

Best Regards,

Makram ABDELLATIF