Michel, It does sound as though there is an issue with one of the
printers or integrators resetting. Your Type55 parameters look
okay to me. Usually Type55 feeds into a Type25 printer. Make sure
that the print time (print interval) is set to 8769 as well (so
long as you want only one value printed at the end of the
simulation.) Another thought is that unless you have to run your simulation for more then a year (ie if the time has to go beyond 8769) then you could set all of the integrator reset times and print times to the variable name "STOP." STOP is a built-in variable that is the hour on which the simulation should end. kind regards, David