Dear Christoph,
I am working with Khaled on this issue.
I am wondering that if we linked the window type 35 to multi-zone building Type 56, how would Type 56 proceed with calculating the energy balance. How could Type 56 take the area of the window into consideration and subtract the area of the wall from it?
The main objective is to perform parametric study for windows to wall ration (WWR).
Thanks in advance,
Oussama
----
Oussama Ibrahim Lebanese University Tel: 961-70-818470 E-mail: oibrahimul@hotmail.com ; oibrahim1984@gmail.com From: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> on behalf of hotline via TRNSYS-users <trnsys-users@lists.onebuilding.org>
Sent: Tuesday, July 3, 2018 10:34 AM To: TRNSYS users mailing list at OneBuilding.org Cc: hotline Subject: Re: [TRNSYS-users] Link between Window type 35a and multi zone building type 56a Hey,
you just need to define Inputs in TRNBuild and then “Update building bariable list” by right click on TYPE 56 in Studio (please have a look into 5.2.3.3. Inputs in 05-MultizoneBuilding Docu). Then you can connect the window type with type 56.
Best, Christoph
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org]
Im Auftrag von khaled al hussein via TRNSYS-users
Dear All could we have a link between Window type 35a and multi zone building type 56a Best regards |