[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] parametric study in buildings



I think that if you are looking to modify the WWR, you have to modify the window AND the wall areas in order to get the same total area as before the modification.
It's possible in TRNSYS 17 by modifying the .b17 file manually or with a script (matlab, python...).

Le mardi 26 juin 2018 à 07:50:14 UTC+1, Oussama Ibrahim via TRNSYS-users <trnsys-users@lists.onebuilding.org> a écrit :


Hello every one,


I am trying to perform parametric study in buildings, where one of the parameters is the windows to wall ratio (WWR). I am defining the area of the walls and I intend to change the area of windows, thus, the area of the window is the parameter under consideration.


Does anyone have an idea if this possible using Trnsys17.


Thanks in advance,


Oussama

----
Oussama Ibrahim
Lebanese University 
Tel: 961-70-818470 
E-mail: oibrahimul@hotmail.com ; oibrahim1984@gmail.com
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org