[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 94 and Type 15



Leen,

Yes.  Set the slope of the surface in Type 15 and then connect the surface outputs from 15 to the inputs of Type 94.

Jeff / TESS

Sent from my iPhone

> On Apr 29, 2018, at 3:47 PM, leen peeters via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:
> 
> Hi,
> 
> type 94 demands for an input for both diffuse and beam radiation on the array, while aslo asking for the slope of the panels. 
> Type 15 calculations the weather data, including on defined slopes. 
> 
> Question is now what exactly is meant with "on the array" for type 94? Does it mean I have to use the slope of the panels as a value in the type 15 too?
> 
> Just to make sure I handle it correctly ...
> 
> Leen
> 
> _______________________________________________
> TRNSYS-users mailing list
> TRNSYS-users@lists.onebuilding.org
> http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org