[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Initial value for outputs



Dear M. Thornton,

Thank you very much for help.

You are totally right, I tried to create a new component but it's not easy. So i'll just modify the initial values like you told me.

But in order to compile the Type 164, and rebuilt the library after modifying the type, should I generate the TRNDLL in MVS (JPEG1) ? By this step Trnsys will be able to take the modifications in consideration ? Is it sure that the other types will not be affected ? 

So step : 1: Modify the type; 2 : Generate TRNDLL in MVS ? 

Thank you in advance

 

On Tue, Nov 14, 2017 at 7:54 PM, Jeff Thornton via TRNSYS-users <trnsys-users@lists.onebuilding.org> wrote:

Ghady,

You wrote "In order to add the initial value outputs in the Type 164 code, I prefer to create a new type and not modify the existed one in Trnsys Library. For that I created a new component using Trnsys 17. I had some difficulties because it’s not the same code writing from defining inputs, outputs and parameters to storage; I managed to copy the code line that I am interested in but the problem remains with the storage array.>

Unless you want to completely re-write a version 16 component in version 17 format (and you are certainly willing to attempt that if you'd like), I would suggest that you leave it in version 16 format and just change the output initialization line as I suggested earlier.  Find the lines:

!set initial output values
OUT(1:NO)=0.d0

and replace them with your initial values:
Out(1) =20.d0
Out(2) = 0.do
etc.

Jeff
---
Jeff Thornton President - TESS LLC 22 N. Carroll Street, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com

On 11/13/2017 7:35 am, Ghady Dib via TRNSYS-users wrote:

Hello,

 

In order to add the initial value outputs in the Type 164 code, I prefer to create a new type and not modify the existed one in Trnsys Library.

 

For that I created a new component using Trnsys 17. I had some difficulties because it’s not the same code writing from defining inputs, outputs and parameters to storage; I managed to copy the code line that I am interested in but the problem remains with the storage array.

 

In fact when I created the new component (from Trnsys), I didn’t notice any place where I can specify my number of storage (Which is equal to 2 in Type 164).

  

Do I set my storage number there:  ‘’Call SetNumberStoredVariables(0,0)’; It’s not like the inputs and parameters where I defined their numbers them in Trnsys.

I have to include (in my new component ''type210'') the storage array in FOUR places just like in type 164a:

 

POST CONVERGENCE MANIPULAITIONS

        CALL getStorageVars(STORED,NS,INFO)

        STORED(1)=STORED(2)

        CALL setStorageVars(STORED,NS,INFO)

 

PERFORM FIRST CALL MANIPULATIONS

  CALL setStorageSize(NS,INFO)

 

PERFORM INITIAL TIMESTEP MANIPULATIONS

        STORED(1:NS) = N_INI       !NO. OF MOLES IN PREVIOUS TIME STEP

        CALL setStorageVars(STORED,NS,INFO)

 

UPDATE STORAGE

        STORED(2) = NGAS

        CALL setStorageVars(STORED,NS,INFO)

 

Are these nomenclatures work in the Type210 created by Trnsys 17? Or I have to include other nomenclatures ? such as getStaticArrayValue ? and for the others ?

 

 

Thank you in advance for your support.  

 
--


Ghady DIB

Doctorant

Laboratoire CETHIL UMR 5008 Groupe Energétique des Systèmes Thermiques et Frigorifiques (ESTF) Département Génie Energétique et Environnement INSA Lyon France

 

 

Tel:+ (33) 6 33 52 96 74

 
 

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org




--



 

 

Ghady DIB

Doctorant

Laboratoire CETHIL UMR 5008
Groupe Energétique des Systèmes Thermiques et Frigorifiques (ESTF)

Département Génie Energétique et Environnement

INSA Lyon
France

Tel:+ (33) 6 33 52 96 74

Attachment: JPEG1.jpg