If the storage fluid sees a wide temperature swing which affects the thermal properties of the fluid, then I would suggest you look at the components in the TESS high-temperature solar library. If not, then Type 534 from TESS or the standard tank model in TRNSYS may be OK for your needs.
Jeff
---
Jeff Thornton President - TESS LLC 22 N. Carroll Street, Madison WI USA 53703 Office: (608) 274-2577 Fax: (608) 278-1475 www.tess-inc.com E-Mail: thornton@tess-inc.com
On 10/03/2017 3:20 am, v ravindra via TRNSYS-users wrote:
What kind of Storage tank Component is best for specifying the following condition. The Heat Transfer fluid gets heated by Solar Energy and the heat is transferred to the Storage Medium in the tank without any mixing between the two fluids. Then the Heat from the Storage medium is transferred to a load which is having a heat transfer fluid without any mixing and just by heat transfer. The heat transfer fluid on the solar side and the load side are the same. The operating temperature range is about 450 degree Celsius.
V.Ravindra
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org