Re: [TRNSYS-users] Wall Heater /TRNBuild



Hello Mohamed,

 

the active layer within trnbuild can be used in a floor or in a wall …

divide the external wall into two walls (with and without active layer), include the defined active layer on the correct side of the wall, change the convective heat transfer to internal calculation …

 

that’s it?!

With sunny regards from Graz,

Richard

 

Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] Im Auftrag von Mohamed Krarouch via TRNSYS-users
Gesendet: Donnerstag, 16. März 2017 15:31
An: trnsys-users@lists.onebuilding.org
Betreff: [TRNSYS-users] Wall Heater /TRNBuild

 

Hi everyone,

 

    The aim of my work is to analyze the energetic performance of Hammam (Turkish bath) heated by the underfloor heating system. I also use the wall heater to connect the pipe to the boiler (copper, polyethylene or aluminum and polyethylene) Which will snake 1 m along the walls to circulate homogeneously hot water, as the floor heating.

I know how to use the active layer on the ground floor, but I don't know how to use the wall heater in TRNbuild.....can anyone help me??

 

Best Regards,

Mohamed

 

--

Krarouch Mohamed

Doctorant en Département Physique

Laboratoire de Mécanique des Fluides et Énergétique 

Faculté des sciences Semlalia

Université Cadi Ayyad
Marrakech