Re: [TRNSYS-users] Vector of data as OUTPUT of a component



Miguel,

  Defining an output for each component of your vectors is the simplest way to proceed. If you do not need to use the elements of those vectors as inputs to other components during the simulation but instead only want them as results then you could set up your component to print them into an output file instead of putting them in the out() array.

kind regards,

 David



On 03/07/2017 07:04, Miguel Angel Reyes via TRNSYS-users wrote:

Hi All,

 

I have created my own TRNSYS component, and it is working fine (encoded, compiled and tracked using MVS2005 project solution). Outputs of my model are 4 temperatures vectors of size 10 each. Vector components are updated every time step.

 

Example:

 

Ta (a1,a2,a3,a4,a5,a6,a7,a8,a9,a10)

Tb (b1,b2,b3,b4,b5,b6,b7,b8,b9,b10)

Tc (c1,c2,c3,c4,c5,c6,c7,c8,c9,c10)

Td (d1,d2,d3,d4,d5,d6,d7,d8,d9,d10)

 

I’d like to know how could I do in order to set that information as output. Do I need to define an output for each component and vector (what will mean having 40 outputs) or is there any direct way to refer OUT(1)=T, being T a vector of 10 components.

 

Hope question can be understood,

 

Miguel

 

---------------------------------------------------

Dr. Miguel Ángel Reyes Belmonte

IMDEA ENERGY Institute

Avda. Ramón de la Sagra, 3

Parque Tecnológico de Móstoles

E-28935 Móstoles, Madrid, Spain

Telf.: +34 91 737 1150

e-mail: miguelangel.reyes@imdea.org

web: http://www.energy.imdea.org

https://es.linkedin.com/pub/miguel-angel-reyes/7b/347/b77

orcid.org/0000-0002-9666-2388

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com