Hi Maria

I suggest you to check if all of your IT, IB and AI connection are right.
In the otherhand you may check your component order (control card-component order). Be sure that type34 components are placed between weather data component and type56 and not after type56.

Best regards
Adrien

Le lun., févr. 13, 2017 à 23:22, Maria Ferrara via TRNSYS-users
<trnsys-users@lists.onebuilding.org> a écrit :

Hello trnsys users, 
while running my simulation in Trnsys 16 I get the following error: 

“ Internal error in solar radiation distribution (sumsitot) of -0.066% at time 11.0000 wave length band no.21:total solar, 2:visual solar, 3: non visual solar”

Any ideas about what could cause that? 

Then, I have a doubt: 
I use Type 34 for simulating fixed shading devices on windows. I set up a dedicated orientation for each wall in which is each window to which is connected one type 34. So, the “receiver” dimensions should be the ones of the wall containing the window or the receiver is the window itself? How the model takes into account the reduction in solar radiation hitting the opaque wall?

Thank you, I will really appreciate any help concerning any of the two questions.