it's an AIR-to-AIR heat pump. I have connected the heat pump with type 56 defining these inputs "inlet-flowrate" and "inlet temperature" in trnbuild for the ventilation rate manager. Now i don't have the output flowrate but i think it's a  less important problem that i can bypass.

thak you


Da: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> per conto di Toni Calabrese via TRNSYS-users <trnsys-users@lists.onebuilding.org>
Inviato: lunedì 13 febbraio 2017 19.09
A: Riccardo Nesa via TRNSYS-users
Oggetto: [TRNSYS-users] R: (no subject)
 

Hi Riccardo,

which kind of heat pump are you using?

If you are using a AIRtoWATER Heat pump, you could define an active layer into the building and connect to the heat pump for example. In case you are using a AIRtoAIR Heat Pump, you could define a VENTILATION Type in TRNBUILD file and you could connect the output of the Heat pump to the input of the VENTILATION system. Did you understand?

 

Toni Calabrese

 

Da: Riccardo Nesa via TRNSYS-users
Inviato: lunedì 13 febbraio 2017 19:03
A: trnsys-users@lists.onebuilding.org
Oggetto: [TRNSYS-users] (no subject)

 

Hi TRNSYS USERS,


i'd like to do a simulation with type 56 (where i designed my building) connected with a heat pump but with this type i can't connect the outlet flowrate of the heat pump directly with the building (i don't want to use the heating type manager in trnbuild).

anybody can help me?


i just want to study the performance of the heat pump and the temperature of the house (with the walls and materials that i decided for it in trnbuild).


thank you