TRNSYS - the TRaNsient SYstem Simulation program The Solar Energy Lab at the University of Wisconsin - Madison, USA Le Centre Scientifique et Technique du Batiment, Sophia Antipolis, France Transsolar Energietechnik GmBH, Stuttgart, Germany Thermal Energy System Specialists, Madison Wisconsin, USA Release 16.00.0037 Listing file for: "C:\Program Files (x86)\Trnsys16\MyProjects\Project31\Project31.dck" *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : The TRNSYS Executable (TRNExe.exe) and main DLL (TRNDll.dll) are located in "C:\Program Files (x86)\Trnsys16\Exe" *** Pre-Processing the TRNSYS EQUATIONs and CONSTANTs to check for fatal errors. *** Pre-Processing of EQUATIONs and CONSTANTs completed with no fatal errors found. *** Evaluating the EQUATIONs and CONSTANTs to determine their initial values. *** Finished evaluating the EQUATIONs and CONSTANTs and ready to begin processing the remainder of the TRNSYS input file. VERSION 16 ******************************************************************************* *** TRNSYS input file (deck) generated by TrnsysStudio *** on Friday, December 09, 2016 at 15:43 *** from TrnsysStudio project: C:\Program Files (x86)\Trnsys16\MyProjects\Project31\Project31.tpf *** *** If you edit this file, use the File/Import TRNSYS Input File function in *** TrnsysStudio to update the project. *** *** If you have problems, questions or suggestions please contact your local *** TRNSYS distributor or mailto:iisibat@cstb.fr *** ******************************************************************************* ******************************************************************************* *** Units ******************************************************************************* ******************************************************************************* *** Control cards ******************************************************************************* * START, STOP and STEP CONSTANTS 3 START=8040 STOP=8208 STEP=1 * User defined CONSTANTS ! Start time End time Time step SIMULATION 8.0400000000000000E+03 8.2080000000000000E+03 1.0000000000000000E+00 ! Integration Convergence TOLERANCES 1.0000000000000002E-03 1.0000000000000002E-03 ! Max iterations Max warnings Trace limit LIMITS ******** ******** ******** ! TRNSYS numerical integration solver method DFQ 1 ! TRNSYS output file width, number of characters WIDTH 80 ! NOLIST statement LIST ! MAP statement ! Solver statement Minimum relaxation factor Maximum relaxation factor SOLVER 0 1.000000000000000 1.000000000000000 ! Nan DEBUG statement NAN_CHECK 0 ! Overwrite DEBUG statement OVERWRITE_CHECK 0 ! EQUATION SOLVER statement EQUATION SOLVING METHOD 0 * Model "Type65d" (Type 65) * UNIT 2 TYPE 65 Type65d *$UNIT_NAME Type65d *$MODEL .\Output\Online Plotter\Online Plotter Without File\Type65d.tmf *$POSITION 674 306 *$LAYER Main # PARAMETERS 12 ! 1 Nb. of left-axis variables ! 2 Nb. of right-axis variables ! 3 Left axis minimum ! 4 Left axis maximum ! 5 Right axis minimum ! 6 Right axis maximum ! 7 Number of plots per simulation ! 8 X-axis gridpoints ! 9 Shut off Online w/o removing ! 10 Logical unit for output file ! 11 Output file units ! 12 Output file delimiter 7.0000000000000000E+00 3.0000000000000000E+00 0.0000000000000000E+00 1.0000000000000000E+03 0.0000000000000000E+00 1.0000000000000000E+03 1.0000000000000000E+00 1.2000000000000000E+01 0.0000000000000000E+00 -1.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 INPUTS 10 ! Type66a:Output-1 ->Left axis variable-1 ! Type66a:Output-7 ->Left axis variable-2 ! Type66a:Output-5 ->Left axis variable-3 ! Type66a:Output-2 ->Left axis variable-4 ! Type109-TMY2:Ambient temperature ->Left axis variable-5 ! Type114:Outlet fluid temperature ->Left axis variable-6 ! Type112b:Outlet humidity ratio ->Left axis variable-7 ! Type66a:Output-3 ->Right axis variable-1 ! Type66a:Output-4 ->Right axis variable-2 ! Type66a:Output-6 ->Right axis variable-3 4,1 4,7 4,5 4,2 7,1 5,1 3,2 4,3 4,4 4,6 *** INITIAL INPUT VALUES T2 Twb2 Tw2 w2 T1 Tw1 w1 Ma2 Mw2 WaterConsumption LABELS 3 Temperatures Heat transfer rates Graph 1 *------------------------------------------------------------------------------ * Model "Type112b" (Type 112) * UNIT 3 TYPE 112 Type112b *$UNIT_NAME Type112b *$MODEL .\Hydronics\Fans\Single Speed\Relative Humidity Inputs\Type112b.tmf *$POSITION 218 296 *$LAYER Main # *$# SINGLE-SPEED FAN PARAMETERS 5 ! 1 Humidity mode ! 2 Rated flow rate ! 3 Rated power ! 4 Motor efficiency ! 5 Motor heat loss fraction 2.0000000000000000E+00 1.0000000000000000E+03 2.6840000000000000E+03 9.0000000000000002E-01 0.0000000000000000E+00 INPUTS 7 ! Type109-TMY2:Ambient temperature ->Inlet air temperature ! [unconnected] Not used (w) ! Type109-TMY2:relative humidity ->Inlet air %RH ! [unconnected] Air flow rate ! Type109-TMY2:Atmospheric pressure ->Inlet air pressure ! [unconnected] Control signal ! [unconnected] Air-side pressure increase 7,1 CONST 7,2 CONST 7,5 CONST CONST *** INITIAL INPUT VALUES 2.0000000000000000E+01 8.0000000000000019E-03 5.0000000000000000E+01 2.0000000000000000E+03 1.0000000000000000E+00 1.0000000000000000E+00 0.0000000000000000E+00 *------------------------------------------------------------------------------ * Model "Type66a" (Type 66) * UNIT 4 TYPE 66 Type66a *$UNIT_NAME Type66a *$MODEL .\Utility\Calling External Programs\EES\Call EES EveryTime\Type66a.tmf *$POSITION 492 302 *$LAYER Main # PARAMETERS 4 ! 1 Input mode ! 2 not used ! 3 Allowable wait ! 4 Number of ouputs 1.0000000000000000E+00 1.0000000000000000E+00 1.0000000000000000E+04 7.0000000000000000E+00 INPUTS 8 ! Type112b:Outlet air temperature ->Input-1 ! Type112b:Outlet air %RH ->Input-2 ! Type114:Outlet fluid temperature ->Input-3 ! Type114:Outlet flow rate ->Input-4 ! Dimensions:V ->Input-5 ! Dimensions:As ->Input-6 ! Type112b:Outlet flow rate ->Input-7 ! Type112b:Outlet air pressure ->Input-8 3,1 3,3 5,1 5,2 V AS 3,4 3,5 *** INITIAL INPUT VALUES 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 0.0000000000000000E+00 LABELS 2 C:\EES32\ees.exe C:\Users\amirreza\Desktop\RCM2.ees *------------------------------------------------------------------------------ * Model "Type114" (Type 114) * UNIT 5 TYPE 114 Type114 *$UNIT_NAME Type114 *$MODEL .\Hydronics\Pumps\Single Speed\Type114.tmf *$POSITION 214 136 *$LAYER Main # *$# SINGLE-SPEED PUMP PARAMETERS 4 ! 1 Rated flow rate ! 2 Fluid specific heat ! 3 Rated power ! 4 Motor heat loss fraction 1.0000000000000000E+03 4.1899999999999995E+00 2.6840000000000000E+03 0.0000000000000000E+00 INPUTS 5 ! [unconnected] Inlet fluid temperature ! [unconnected] Inlet fluid flow rate ! [unconnected] Control signal ! [unconnected] Overall pump efficiency ! [unconnected] Motor efficiency CONST CONST CONST CONST CONST *** INITIAL INPUT VALUES 2.0000000000000000E+01 0.0000000000000000E+00 1.0000000000000000E+00 6.0000000000000009E-01 9.0000000000000002E-01 *------------------------------------------------------------------------------ * EQUATIONS "Dimensions" * EQUATIONS 2 V = 0.1 As = 1 *$UNIT_NAME Dimensions *$LAYER Main *$POSITION 490 114 *------------------------------------------------------------------------------ * Model "Type109-TMY2" (Type 109) * UNIT 7 TYPE 109 Type109-TMY2 *$UNIT_NAME Type109-TMY2 *$MODEL .\Weather Data Reading and Processing\Standard Format\TMY2\Type109-TMY2.tmf *$POSITION 73 296 *$LAYER Weather - Data Files # PARAMETERS 4 ! 1 Data Reader Mode ! 2 Logical unit ! 3 Sky model for diffuse radiation ! 4 Tracking mode 2.0000000000000000E+00 3.0000000000000000E+01 4.0000000000000000E+00 1.0000000000000000E+00 INPUTS 3 ! [unconnected] Ground reflectance ! [unconnected] Slope of surface ! [unconnected] Azimuth of surface CONST CONST CONST *** INITIAL INPUT VALUES 2.0000000000000001E-01 0.0000000000000000E+00 0.0000000000000000E+00 *** External files ASSIGN C:\Program Files (x86)\Trnsys16\Weather\Meteonorm\Australia-Oceania\AU-Sydney-947680.tm2 30 *|? Weather data file |1000 *------------------------------------------------------------------------------ END TRANSIENT SIMULATION STARTING AT TIME = 8.0400000000000000E+03 STOPPING AT TIME = 8.2080000000000000E+03 TIMESTEP = 1 / 1 DIFFERENTIAL EQUATION ERROR TOLERANCE = 1.0000000000000002E-03 ALGEBRAIC CONVERGENCE TOLERANCE = 1.0000000000000002E-03 DIFFERENTIAL EQUATIONS SOLVED BY MODIFIED EULER *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : The following Types were loaded from TRNDll.dll: Type65, Type112, Type66, Type114, Type109 *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSApplicationsLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSControlsLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSGHPLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSGreenBuildingLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSGroundCouplingLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSHVACLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSHydronicsLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSLoadsAndStructuresLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSOptimizationLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSSolarLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSStorageLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "TESSUtilityLibrary_ReleaseVersion201.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type155.dll" was found but not loaded since Type 155 is not used in the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "type203.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type203Lib.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type62.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type801.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "type803.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type804.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type806.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type810.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available Message : "Type860.dll" was found but did not contain any components from the input file. *** Notice at time : 0.000000 Generated by Unit : Not applicable or not available Generated by Type : Not applicable or not available TRNSYS Message 199 : TRNSYS found at least one user DLL in the UserLib directory. (Note: Only DLL's including Types that are used in the simulation are loaded) Reported information : 0 user DLLs were loaded after searching in "C:\Program Files (x86)\Trnsys16\UserLib" *** Warning at time : 8041.000000 Generated by Unit : 7 Generated by Type : 109 TRNSYS Message 33 : An inconsistent connection has been defined in the TRNSYS input file. The desired units for the input do not match the units of the connected output as specified in the component model. The discrepancy is listed below. Reported information : Not available Unit / Type / Output / Var.Type Connected to Unit / Type / Input / Var.Type --------------------------------------------------------------- 7 109 5 DM1 -----------> 3 112 5 PR4 *** The TRNSYS components will be called in the following order: Unit # 3 Type # 112 Unit # 4 Type # 66 Unit # 5 Type # 114 Unit # 7 Type # 109 Unit # 2 Type # 65 *** WARNING IN UNIT 3 TYPE 112 AT TIME 8041.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8042.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8043.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8044.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8045.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8046.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8047.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8048.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8049.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8050.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8051.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8052.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8053.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8054.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8055.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8056.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8057.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8058.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8059.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8060.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8061.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8062.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8063.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8064.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8065.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8066.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8067.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8068.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8069.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8070.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8071.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8072.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8073.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8074.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** WARNING IN UNIT 3 TYPE 112 AT TIME 8075.0000 *** UNIT NUMBER 3 HAS CALLED THE PSYCH ROUTINE WITH A TOTAL PRESSURE GREATER THAN 5 ATMOSPHERES. BEWARE THAT THE IDEAL GAS RELATIONS USED IN THE PSYCHRO- METRICS ARE NOT ACCURATE AT HIGHER PRESSURES. *** Fatal Error at time : 8075.000000 Generated by Unit : 4 Generated by Type : 66 Message : Clipboard data contains characters instead of numbers. ********************************************************************************************************* The Following UNIT Numbers, TYPE Numbers, and Logical Units Were Used in the Supplied TRNSYS Input File: 2 65 4 3 66 6 4 109 9 5 112 30 7 114 ********************************************************************************************************* Total TRNSYS Calculation Time: 22.5500 Seconds TRNSYS Time Breakdown by Unit Number Unit 2: 0.000000 Seconds Unit 3: 0.000000 Seconds Unit 4: 20.780001 Seconds Unit 5: 0.000000 Seconds Unit 7: 0.010000 Seconds TRNSYS Time Breakdown by Type Number Type 65: 0.000000 Seconds Type 66: 20.780001 Seconds Type 109: 0.010000 Seconds Type 112: 0.000000 Seconds Type 114: 0.000000 Seconds Total Calculation Time Inside of the Types: 20.7900 Seconds TRNSYS Iterative Call Breakdown by Unit Number Unit 2: 37 Calls Unit 3: 107 Calls Unit 4: 107 Calls Unit 5: 72 Calls Unit 7: 71 Calls
Attachment:
Project31.dck
Description: Binary data
Attachment:
Project31.log
Description: Binary data
Attachment:
Project31.PTI
Description: Binary data
Attachment:
Project31.tpf
Description: Binary data
Attachment:
RCM2.ees
Description: Binary data