[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] radiation calculation



Hi Karol,

 

Try using the Type21 Time Values (Utility folder) instead of the weather data file time values.

Kind regards,

Alastair McDowell

Engineering Consultant

Energy Analysis & Engineering – Enabling innovation for a sustainable future

T: +61 450 600 842

E: alastair.mcdowell@energyae.com

608 Harris St Sydney NSW 2007 Australia | http://www.energyae.com

 

From: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org] On Behalf Of Karol BANDURSKI via TRNSYS-users
Sent: Thursday, July 21, 2016 6:24 PM
To: TRNSYS-users@lists.onebuilding.org
Subject: [TRNSYS-users] radiation calculation

 

Dear All,

 

I have prepared simple file (attached) to generate total radiation on different surface from existing TMY2 file.

 

The problem is that in generated files the first hour of month is printed as the first hour of next day but previous month.

For example instead of 1st of January 0 hour I get 32nd of December 0 hour…

 

Do you know how can I fix this bug?

 

Regards,

Karol

 

------------------------------------------------

Karol Bandurski MSc.

Institute of Environmental Engineering

Poznan University of Technology

www.put.poznan.pl/~karol.bandurski

www.ee.put.poznan.pl