Dear Adnan, please make sure that all other heat transfer effects (solar radiation, internal gains, convection, infiltration) besides heat flow through walls
are switched off! you can use NType 19…22 to determine the heat flows at the front and back side of the wall. And please keep in mind that TRNSYS will simulate capacitive
effects, too.
Best _________________________________________________________________________________________________ Jakob Merk TRNSYS Software Team
Curiestraße 2 70563 Stuttgart Fax: +49 711 67976-11 Web: www.trnsys.de
Von: TRNSYS-users [mailto:trnsys-users-bounces@lists.onebuilding.org]
Im Auftrag von Adnan Upm Spain Thanks Merk for your reply... I am using Ntype2 sensible heating demand and one out put Ntype 906 which give energy balance in it system also gives same value for heating. Regards Sent from my Sony Xperia™ smartphone
Dear Adnan, your approach makes sense to me. TRNSYS does calculate heat transport for each time
step and is not using a fixed U-Value. Which TRNSYS outputs did use for
q= convective and radiative heat loss ? I guess that using a wrong output could have coused your problem… Sincerely yours _________________________________________________________________________________________________ Jakob Merk TRNSYS Software Team
Curiestraße 2 70563 Stuttgart Fax: +49 711 67976-11 Web: www.trnsys.de
Von: TRNSYS-users
[mailto:trnsys-users-bounces@lists.onebuilding.org]
Im Auftrag von adnan rasheed hi everyone, i have one question i am stuck with this problem. 1- i want heating a room having one window, by using type 56 inside temp = 10, 20, 30,.... dry bulk temp= ambient temp = outside = 0 sky temp = 0 and -20 i wanna see the change in overall heat transfer coefficient = u-value of glazing (window) by changing inside temperature using this equation U = Q / A(T) where U = U-value q= convective and radiative heat loss A = Area of window T = ambient and inside temp difference. i get results but TRNSYS giving me almost the same value of U for all temp difference. trend is not same as experimental U-value trend according to change in
inside temp. anyone please help me with this is it possible to calculate U-value of window like this. or trnsys use fix U-value for the calculation of heat load. thanks in advance. for killing your time. Regards Adnan |