Dear Trnsys users, I am currently working on a very massive building, with many zones and very with high thermal inertia (concrete wall from 60 to 120 cm of thickness). The model takes 40 minutes to calculate 1 month.
I observe than after one month, final temperatures in zones are still very depending on initial temperatures. For this reason, I tried to adjust initial temperature to be nearer to expected final temperatures (in the
order of 35-40°C). However, in the first part of the simulation, temperatures drop quickly to 25-30°C, depending on the zone. This is quite surprising, considering that there are no heat losses and there are heat gains. The only explication
I found is that surface temperatures are not initialized to initial temperature of the zone, and thermal mass takes time to warm up. Do you know if there is a way to force surface temperatures to zone temperatures at the beginning of a simulation ? Thank you ! Best regards, Marcello Caciolo