Hi Bharath,


This is usually related to the a component model with an error in the Fortran. Info (6) is related to the number of outputs reserved for outs, however more outputs have been written into the model without being reserved.


Have you written a new Type, edited an existing Type Fortran, or added a custom Component that is not standard?

It may be another component rather than TYPE 110 causing an issue. Can you back-track to figure out which component?

Cheers,
TG


________________________________
From: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> on behalf of Bharath Seshadri <s.bharath@ntu.edu.sg>
Sent: Friday, 24 July 2015 1:40 AM
To: trnsys-users@lists.onebuilding.org
Subject: [TRNSYS-users] OUT array location error


Dear Fellow TRNSYS-users,

Has anyone come across this error “An OUTPUT from the specified component model has been written to the global OUT array in a location beyond the allocated number of outputs from the model. Please check the component carefully to ensure that INFO(6) is set correctly. The simulation has been aborted to avoid problems caused by over-writing the outputs from other component models”. The component in question is a type 110 variable flow pump.

Greatly appreciate your advice/inputs. Thank you!

Bests, Bharath

Bharath Seshadri (Mr)| Research Associate | Energy Research Institute @ NTU (ERI@N) | Nanyang Technological University, 1 Cleantech Loop, #06-09, CleanTech One, Singapore 637141 (Map)<http://erian.ntu.edu.sg/ContactUs/Documents/CT%20One%20Map_visitors.pdf> | Mob: (65) 9663-5165 Tel: (65) 6592-3284 GMT+8h | Fax: (65) 6694-6217 | Email: s.bharath@ntu.edu.sg<mailto:s.bharath@ntu.edu.sg> | Web: www.ntu.edu.sg<http://www.ntu.edu.sg/> & http://erian.ntu.edu.sg<http://erian.ntu.edu.sg/>

[SG50]
________________________________
CONFIDENTIALITY: This email is intended solely for the person(s) named and may be confidential and/or privileged. If you are not the intended recipient, please delete it, notify us and do not copy, use, or disclose its contents.
Towards a sustainable earth: Print only when necessary. Thank you.

Attachment(s)
ATT00001.txt

This email is a service from TRNSYS GURU. Delivered by Zendesk
Message-Id:42AXJ4J2_55b602a831788_32c23f87070cd320712731_sprut