[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 56 validation references



Software validation norms: VDI 6020, DIN EN 15265, DIN EN 15255.

2015-06-01 23:27 GMT+02:00 David BRADLEY <d.bradley@tess-inc.com>:
Marcello,
  There is a basic list of references for Type56 in the 05-MultizoneBuilding documentation (section 5.4.7). In the US, building energy modeling tools are "validated" by running them through a series of tests that are described in ASHRAE Standard 140 (there is an analogous BESTEST standard as well). So long as the results of a software fall within acceptable ranges as defined in the Standard then the software is said to pass the Standard. The range of acceptable results is defined by the results that were obtained quite a few years ago by third parties (i.e. not developers) running some industry standard software tools. A previous version of TRNSYS is one of the industry standard software tools that was used in setting the acceptable range for Standard140.

  I would appreciate if others could add information about validation standards outside the US.
kind regards,
 David





On 6/1/2015 4:24 AM, marcello.caciolo@cofelyaxima-gdfsuez.com wrote:

Dear TRNSYS users,

 

In order to convince a partner on the pertinence of using Type 56 to model a building, I need to collect some references to validation tests of the building model versus measurements, in test cells or real buildings.

 

Could you please give me some references of this type ?

 

Thank you in advance.

 

Best regards,

Marcello Caciolo
Responsable Outils et Méthodes d'Analyse Energétique

cid:image003.jpg@01CD4E08.954D04D0

Cellule Efficacité Energétique et Environnementale

INGÉNIERIE PROJETS
15 rue Nina Simone
CS 39601 - 44096 Nantes cedex 1

Tél.: +33 02 40 41 06 57
marcello.caciolo@cofelyaxima-gdfsuez.com

Le 26 mai 2015, nous emménageons au 15 rue Nina Simone – CS 39601 – 44096 Nantes cedex 1

Nos numéros de téléphone restent inchangés

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org