Meer,
This was an bug in TRNEdit that was fixed in the september 2014
release (v17.02.0004). Please check your trnsys.ini file
(..\Trnsys17\trnsys.ini) by opening it with a text editor and if you
have an earlier version, please contact your distributor for the
update.
kind regards,
David
On 5/18/2015 1:18 PM, A. M wrote:
Dear all,
im doing parametric study for the area of the collector. I
defined the area of the collector in equation component and set
Area collector as string. and then i connected the area from the
equation to "Totals" printer.
After that, i opened TRNedit to conduct my parametric study. I
changed the area of collector to be a constant.
However, when i run the simulation it gives me that file doesnt
exist.
Did i miss any step ?
Thanks !
Meer