[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] TRNSYS-users Digest, Vol 124, Issue 20



Hi,

Is there a way to calculate C02 footprint and greenhouse gas emissions  using TRNSYS?

Also is there any way to change a person's behaviour during the day in TRNBuild?

TRNBuild only let's me select one behaviour.

Is it possible to program different kinds of behaviour during the day?

Best regards,

Diogo Remoaldo

On Wed, Apr 15, 2015 at 9:05 PM, <trnsys-users-request@lists.onebuilding.org> wrote:
Send TRNSYS-users mailing list submissions to
        trnsys-users@lists.onebuilding.org

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

or, via email, send a message with subject or body 'help' to
        trnsys-users-request@lists.onebuilding.org

You can reach the person managing the list at
        trnsys-users-owner@lists.onebuilding.org

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

   1. Genopt trnbuild error (Martin Berov)
   2. Re: Genopt trnbuild error (mcdowell@tess-inc.com)


---------- Forwarded message ----------
From: Martin Berov <martber88@gmail.com>
To: "TRNSYS users mailing list at the Solar Energy Lab, UW-Madison" <trnsys-users@cae.wisc.edu>
Cc: 
Date: Tue, 14 Apr 2015 21:06:12 +0200
Subject: [TRNSYS-users] Genopt trnbuild error
Hi,

I'm using Genopt to optimize parameters of solar heating system (first just the collector area and slope). I compiled the input file, defined the variables in genopt i.e. everything as required. bu when I run the optimization i get error message as table where is written:

Trnbuild
Surf-No                                       Description                                       Comment
-1                                          no OUTPUT's specified                     please add at least one output

In the Trnsys simulation environment I get output results (the model is properly functioning)

Do you have idea what could be the problem?

Best Regards
Martin



---------- Forwarded message ----------
From: mcdowell@tess-inc.com
To: "TRNSYS users mailing list at OneBuilding.org" <trnsys-users@lists.onebuilding.org>
Cc: 
Date: Wed, 15 Apr 2015 11:22:06 -0500
Subject: Re: [TRNSYS-users] Genopt trnbuild error

Martin Berov -

It is not finding your building model file when it starts the simulation.  GenOpt moves the files to run a simulation so you need to make sure all paths for files are complete.

Regards,

Tim

 

---
Timothy P. McDowell Executive Vice President Thermal Energy System Specialists, LLC 22 N Carroll St, Suite 370 Madison, WI 53703 608-274-2577

On 2015-04-14 14:06, Martin Berov wrote:

Hi,
 
I'm using Genopt to optimize parameters of solar heating system (first just the collector area and slope). I compiled the input file, defined the variables in genopt i.e. everything as required. bu when I run the optimization i get error message as table where is written:
 
Trnbuild
Surf-No                                       Description                                       Comment
-1                                          no OUTPUT's specified                     please add at least one output
 
In the Trnsys simulation environment I get output results (the model is properly functioning)
 
Do you have idea what could be the problem?
 
Best Regards
Martin
 

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org