[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] TRNSYS Error message 105



Fabio,
  There are two parts to getting a Type in an external DLL to load and run properly. The first is that the dll must be located in the correct spot, which you have done (thank you for taking the time to look through the log and list files for related information and for putting everything in your email). The second part is that the name of the routines inside the dll must be correctly exported. This is something that the author of the Type needs to do (in this case Transsolar). If you recently updated from Trnsys17.1 to Trnsys17.2 then you simply need to ask Transsolar for an updated version of Type399.
Kind regards,
 David

 
On 1/12/2015 09:34, Fabio Grossule wrote:
Hi TRNSYS-users,

I built a model in TRNSYS but when I run the simulation it doesn't work and I keep on getting the following error message:

TRNSYS Message    105 : A TYPE was called in the TRNSYS input file but was either not linked into trndll.dll or was not found in an external dll. A dummy subroutine was called in its place. Please link the TYPE or remove it from the input file  Reported information  :  Type399 could not be located in either the trndll.dll or in an external dll. Please relink theTRNDll.dll including this Type or make sure that an external DLL in the \UserLib\DebugDLLs and \UserLib\ReleaseDLLs folders contain the Type.

The component 399 models phase change materials (PCM) and it's not included in the standard TRNSYS libraries.
I consulted some previous discussion related to this topic and I did this:
- I put the .dll file in the \UserLib\DebugDLLs and \UserLib\ReleaseDLLs folders
- I put the sourcecode file .f90 in the TRNSYS folder Sourcecode/types
But it doesn't work either.

I checked the .log file as well and there is written:

Notice at time        :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    Message               : "Type399.dll" was found but did not contain any components from the input file.

So I think that there might be a problem in the deck file.

Please, do you have any suggestions about how to fix the error?

Best regards,
Fabio


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com