[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] evacuated tube type538



Saja,
  Take a look at the "notices" that are listed in the *.lst and *.log files from your simulation (they'll probably be located in the same place as the Studio project file (*.tpf). The early notices should contain some information as to whether any external DLLs were found in the userlib directory and if any external components (such as Type538) were found and successfully loaded. You should see something like:

*** Notice at time        :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    Message               : The following Types were loaded from "TESSSolarLibrary_v17.1.00.dll": Type538

or perhaps:

*** Notice at time        :         0.000000
    Generated by Unit     : Not applicable or not available
    Generated by Type     : Not applicable or not available
    Message               : "TESSSolarLibrary_v17.1.00.dll" was found but did not contain any components from the input file.

If you don't see any such message it may mean that the TESS Libraries aren't installed in the correct location.
Kind regards,
 David



On 5/16/2014 11:26, saja al-rifai wrote:
dear all

I have an problem in using evacuated tube type 538 from the new TESS library, the simulation stops after few seconds of starting, and trnsys give me a two message ,
 the first message: (A type was called in the TRNSYS input file but was either not linked into trndll.dll or was not found in an external dll.  a dummy subroutine was called in its place. please link the type or remove it from the input file)
the second message: ( error reading data stored in logical unit. note: the reported logical unit number may be automatically or internally assigned, or you may have specified the incorrect number of independent variables) 

how i can solve this problem?  the external file used to read the IAM is the (evacuatedTubeSolarCollector-IAMData.dat)

  saja


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com