Hi, The names of the thermal airnodes are: F2_SWNW_CMA, F2_SW_CMA and F2_NW_CMA The ID links where it happens are: ID 4 from node F1_SW_CMA to node F2_SWNW_CMA, from height 2.9 to height 0 ID 5 from node F2_SWNW_CMA to node F2_SW_CMA, from height 5.45 to height 0 ID 6 from node F2_SW_CMA to exterior node EN_SW, from height 0 to height 10.8 ID 10 from node F1_NE_CMA2 to node F2_SWNW_CMA, from height 2.9 to height 0 ID 11 from node F2_SWNW_CMA to node F2_NW_CMA, from height 5.45 to height 0 ID 12 from node F2_NW_CMA to exterior node EN_NW, from height 0 to height 10.8 Please find attached the .b17 file. Thank you annamaria From: trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu]
On Behalf Of hotline Dear Annamaria, What are the names of the thermal airnodes/zones? Do the name of the modified airnode has “PA” in the name? Can you send me the b17 and the link ID where this happens. Best regards, Transsolar Software Team ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ TRNSYS Userday 2014: This years TRNSYS Userday will be taking place on 23rd May in Stuttgart.
There are still free spots and we are looking forward to welcoming you here in Stuttgart.
The TRNSYS Userday is an annual event where TRNSYS Users meet and exchange ideas and experiences. Developers of TRNSYS will be present and happy to discuss
any problems and new ideas. Presentations by TRNSYS users about their TRNSYS experiences, projects or developments will make up the main program of the userday. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ English TRNSYS Course May 2014: We provide TRNSYS courses in
English from May 13th until 16th in Stuttgart, Germany. For further information follow this Link
http://www.transsolar.com/__software/docs/trnsys/trnsys_schulung_en.htm If you are interested to attend to the courses, please register by an E-Mail to
hotline@transsolar.com with your name and the name of your company or institute. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Von:
trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu]
Im Auftrag von Belleri Annamaria Dear TRNSYS users, I am using TRNFLOW to model airflows between zones. I have horizontal openings to connect ground floor zones to first floor zones so I set the own height factor of the large opening to 0. When I save the bui file, the links to the thermal airnode are replaced with constant pressure nodes, with 0 Pa pressure and the Trnbuild stops working. Why is this happening? Thanks in advance, Annamaria _ _ Annamaria Belleri EURAC research t +39 0471 055 658 f +39 0471 055 039 m +39 333 8569899 EURAC research Legal Seat Viale Druso 1, I-39100 Bolzano This transmission is intended only for the use of the addressee and may contain confidential or legally privileged information.
P Think before you print |
Attachment:
VA_ventcool.b17