Re: [TRNSYS-users] Data generated using TRNSYS



Metkell,
  The plotter (Type65) is just plotting the outputs of other components that are being passed to it as its inputs. If you want to have a file written out at the end of your simulation containing the values that were plotted then you can either use a printer component such as Type25 or you can replace the Type65 with the version of Type65 that automatically creates an output file containing the plotted numbers (Type65c)
David
 


On 3/28/2014 08:55, metkell yebiyo wrote:
Dear TRNSYS users,

Does anyone know how to get hold of the raw data generated by TRNSYS. Say you have a model of GSHP, once you run the model it will generate COP, flow and return temperatures etc. Now how would you get hold of or transfer the raw data you are seeing on the graph please?