Igor, Type4 takes the tank volume and the height of each tank node as parameters. You'll find one "height of node-X" parameter for each node that you specify. The model calculates the tank diameter from the volume and the overall height (the sum of the node heights). Regards, David On 3/8/2014 14:32, Igor Seso wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |