Thank you. I have done what you suggest (even simulate the building withouth shadows) but the error message is the same. Does it means the problem is in the building?


2014/1/23 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
        trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
        https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
        trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
        trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

   1. Re: Shading Matrix (hotline)


---------- Missatge reenviat ----------
From: hotline <hotline@Transsolar.com>
To: "'TRNSYS users mailing list at the Solar Energy Lab, UW-Madison'" <trnsys-users@cae.wisc.edu>
Cc: 
Date: Thu, 23 Jan 2014 10:09:17 +0000
Subject: Re: [TRNSYS-users] Shading Matrix

Dear Toni,

 

problems with the shading matrix usually appear when there are too many shading surfaces in the model. Try to delete

all unnecessary shading surfaces, if it still doesn’t work generate the insolation matrix without  shadings to check if its

a building or shading surface problem.

 

Best

 

__________________________________________________________________________________________________

 

Jochen Lam

TRNSYS Software Team


Transsolar Energietechnik GmbH

Curiestraße 2

70563 Stuttgart

Fax:        +49 711 67976-11
Email:    jlam@transsolar.com

Web:      www.trnsys.de

 

Von: trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] Im Auftrag von Toni Herena
Gesendet: Donnerstag, 23. Januar 2014 10:34
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] Shading Matrix

 

Hi everyone, 

 

I'm currently modeling a building with some shading devices in facades (louvres). First modeled in sketchup3D and then imported to trnsys. There are some zones that are not convex, so I choose only the detailed radiation model for the right zones that can be calculated this way, and let the other zones (not important for the energy demand) with the standard radiation model.

 

I can generate the view factor matrix without any problem, but when I try to generate the shading/isolation matrix an error occurs and it doesn't create any file (well, it creates only a nearly empty .log file).

 

I must say that there are several zones in this building. I have made some test with other building to check if my shading isolation generator were working well and it performed ok. So is it a problem attached to this building? to the file? to the number of shading groups?

 

Thank you in advance and reggards.

 

 

 

Imatge en línia 1

 

 

 

--
Toni Herena

Responsable de projectes
Àrea Tècnica

Sistemes Avançats d'Energia Solar Tèrmica SCCL
C/ Roger de Llúria, 29 3r 2a 08009 Barcelona
Tel: (+34) 93 342 47 55 Fax: (+34) 93 342 47 56

toni.herena@aiguasol.coop
http://www.aiguasol.coop

 


P Contribuye con el Medio Ambiente y no imprimas este e-mail si no es imprescindibleneration 


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users




--
Toni Herena

Responsable de projectes
Àrea Tècnica


Sistemes Avançats d'Energia Solar Tèrmica SCCL
C/ Roger de Llúria, 29 3r 2a 08009 Barcelona
Tel: (+34) 93 342 47 55 Fax: (+34) 93 342 47 56

toni.herena@aiguasol.coop
http://www.aiguasol.coop


Contribuye con el Medio Ambiente y no imprimas este e-mail si no es imprescindible