[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] How to sonstruct a dynamic building model in trnsys



Hi,

 

Type 56 can handle a multi-zonal models. You can model all layers in one building model.

 

Best

__________________________________________________________________________________________________

 

Jochen Lam

TRNSYS Software Team


Transsolar Energietechnik GmbH

Curiestraße 2

70563 Stuttgart

Fax:        +49 711 67976-11
Email:    jlam@transsolar.com

Web:      www.trnsys.de

 

Von: trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] Im Auftrag von Cheng Qi
Gesendet: Dienstag, 19. November 2013 09:57
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] How to sonstruct a dynamic building model in trnsys

 

Hi,

 

I have to construct a dynamic building-metro, but only one Type 56 can be used in the model. And the metro station has 3 layers (platform, concourse, entrance). Given the dynamic soil temperature and tunnel temperature, which model is suitable for this situation? Or how can I construct this building model?

 

Regards

Qi Cheng