Hi, Type 56 can handle a multi-zonal models. You can model all layers in one building model. Best __________________________________________________________________________________________________ Jochen Lam TRNSYS
Software Team
Curiestraße 2 70563 Stuttgart Fax: +49 711 67976-11 Web: www.trnsys.de
Von: trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu]
Im Auftrag von Cheng Qi Hi, I have to construct a dynamic building-metro, but only one Type 56 can be used in the model. And the metro station has 3 layers (platform, concourse, entrance). Given the dynamic soil temperature and tunnel temperature, which model is suitable
for this situation? Or how can I construct this building model? Regards Qi Cheng |