Re: [TRNSYS-users] Mechanical versus Natural ventilation



With Trnflow, it's possible to deal with mechanical and natural ventilation in the same time.
In that way, you will have to define your natural and mechanical ventilation system with trnflow (this could be quite complex), and not in ventilation manager.
Best regards



www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
62, Rue du Bolliet
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email
Le 05/07/2013 15:00, MAIS, Thomas a écrit :

Thanks Adrien.

 

But my goal is to cool down an office with natural ventilation while a mechanical ventilation (for the airflow complying with the requirements of regulations) is running.

So if I get your point, it’s impossible to evaluate AT THE SAME TIME an airflow from mechanical and natural ventilation… Is it correct ?

 

See U

 

De : trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] De la part de ITF - Adrien JEZEQUEL
Envoyé : vendredi 5 juillet 2013 11:56
À : trnsys-users@cae.wisc.edu
Objet : Re: [TRNSYS-users] Mechanical versus Natural ventilation

 

Dear Thomas,

When you use trnflow, mechanical ventilation defined in ventilation manager in trnbuild are set to 0 and airflows are evaluated with trnflow.
With mechanical ventilation, it's easier to use ventilation manager instead of trnflow.
If you want to use mechanical and natural ventilation, you may use an input called TRNFLOW_ON (for example) and connect it to type 56 :

  • when mechanical ventilation is used, TRNFLOW_ON = 0 (airflows are calculated with ventilation type manager)
  • when natural ventilation is necessary, TRNFLOW_ON = 1 (airflows are calculated with trnflow)

Best regards


www.itf.biz
www.itf.biz

Adrien JEZEQUEL
Simulations Thermiques Dynamiques

ITF

62, Rue du Bolliet
73230 St Alban Leysse
FRANCE

Phone :
Fax :
Mail:

+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz

Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email

Le 05/07/2013 11:33, MAIS, Thomas a écrit :

Hello T-users,

 

I’m facing an issue using TRNFlow with TRNSYS.

It seems that Natural ventilation applied thanks to TRNFlow makes the mechanical ventilation (apply in the BUILD or in the STUDIO) disappear…

 

In other words, I think that natural AND mechanical ventilation can’t be simulated at the same time.

 

1.      Am I right ?

2.      Is there any possibilities to “fix” it ?

 

Thanks a lot !

 

 


Thomas Mais

Stagiaire Construction Durable

 





 

Bouygues Bâtiment

Ouvrages Publics

2, rue Transversale
92635 Gennevilliers Cedex
www.bouygues-batiment-ile-de-france.com

 

 

 

 