[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] Help "defining the borehole energy in Type 557"






Dear TRNSYS users,

 

I am wondering how to calculate the internal energy change of the borehole heat exchangers using Type 557:

 

Uborehole = Qborehole-(Qtop+Qside+Qbelow)

 

Is the formula right?

 

Qborehole: Average heat transfer rate

Qtop: Heat loss through top of storage

Qside: Heat loss through side of storage

Qbelow: Heat loss through bottom of storage

 

Many thanks!

 

Regards,

Su Huang

Ph.D Candidate in Sustainable Buildings Research Centre

University of Wollongong  

Email: sh377@uowmail.edu.au