Hei Eirik,
To avoid the hassle of using an integrator and a printer, you can use the type 46 Printegrator (and modify parameter 4, in your case set it to 8760 hrs).
Regards,
Ciarán
From: trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] On Behalf Of Eirik Ask Straalberg
Sent: 29. huhtikuuta 2013 18:03
To: trnsys-users@cae.wisc.edu
Subject: [TRNSYS-users] Printing yearly results
Hi.
If I simulate many years and want to integrate and print yearly results, which module(s) should I use. Have tried Type24 integrator combined with Type25b printer and set intervals like -12 (minus for months), but all I get Is monthly results.
Thank you for your help.
Eirik
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users