[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] naturel ventilation



Hi,

It seems to me that you have some document about TRNFlow in Help menu if you have this plug-in:

 

From: MAIS, Thomas [mailto:t.mais@bouygues-construction.com]
Sent: Tuesday, April 16, 2013 4:02 PM
To: TRNSYS users mailing list at the Solar Energy Lab, UW-Madison
Subject: Re: [TRNSYS-users] naturel ventilation

 

Hello everyone,

I’m studying natural ventilation in school buildings. I already work on TRNSYS so I would like to use the TRNFLOW plug-in.

Is anybody got a tutorial or something like that ? It would be very kind.

Thanks.

Thomas

 

De : trnsys-users-bounces@cae.wisc.edu [mailto:trnsys-users-bounces@cae.wisc.edu] De la part de Karol Bandurski
Envoyé : mardi 26 mars 2013 14:59
À : 'TRNSYS users mailing list at the Solar Energy Lab, UW-Madison'
Objet : Re: [TRNSYS-users] naturel ventilation

 

Hi,

 

Honestly  firstly it should be stated that natural ventilation is so complex phenomena that simulation of this issue is very difficult – there is a lot of uncertainty (e.g. wind Cp value)

 

Using Type 56 (TRNBuild) you can only define natural ventilation (infiltration, ventilation mode, coupling flow of walls).

 

To simulate natural ventilation accurately you should try to use CFD software (Fluent/ANSYS, OpenFOAM-HVACTool, OpenFOAM-Helyx), there is possibility to coupling this softs with TRNSYS e.g. type 101.

 

You can try to simulate it in more coarse way using airflow network method/software – e.g. Contam, ESP-r or commercial TRNBuild plug-in: TRNFLOW.

There is possibility to coupling Contam or ESP-r model with TRNBuild – see type 97 and 130.

 

Contam is free airflow and contaminant distribution simulation software, ESP-r is free building performance (both thermal and airflow) simulation software.

 

Good luck,

Karol

 

 

 

 

 

From: jihad alaoui sosse [mailto:sys.energie@gmail.com]
Sent: Monday, March 25, 2013 4:09 PM
To: TRNSYS-users@cae.wisc.edu
Subject: [TRNSYS-users] naturel vantilation

 

how to model a naturel ventilation in a multizone building 

Cordialy.

--

                                              

Jihad Alaoui Sosse

Ingénieur d'étude

Département Energie

Tél : O648883325 ;

Courriel : sys.energie@gmail.com

NOVEC,  Filiale de CDG Développement - Groupe CDG

Angle Avenue Annakhil et Mehdi Ben Barka

Espace les Palmiers – Hay Riad – Rabat - MAROC

Site web : www.novec.ma

 

P Avant d'imprimer, pensez à l'environnement !

 

 
--
Les donnees et renseignements contenus dans ce message sont personnels, confidentiels et secrets. Toute publication, utilisation ou diffusion, meme partielle, doit etre autorisee. Si vous n'etes pas le bon destinataire, nous vous demandons de ne pas lire, copier, utiliser ou divulguer cette communication. Nous vous prions de notifier cette erreur a l'expediteur et d'effacer immediatement cette communication de votre systeme.
 
Any data and information contained in this electronic mail is personal, confidential and secret. Any total or partial publication, use or distribution must be authorized. If you are not the right addressee, we ask you not to read, copy, use or disclose this communication. Please notify this error to the sender and erase at once this communication from your system.