Re: [TRNSYS-users] PTC solar field model



I guess I don't quite understand your question. Type 1262 is a model for collector array shading. The entire array that is self-shaded needs to modeled in a single Type 1262.

Regards,

Tim

---
Timothy P. McDowell
Executive Vice President
Thermal Energy System Specialists, LLC
22 N Carroll St, Suite 370
Madison, WI 53703
608-274-2577

On 2013-03-20 18:14, Tufan AKBA wrote:
Hello,

I am using Type 1262 for modeling PTC field (and I have Trnsys and
TESS lib. ver. 17) but in order to make a collector field is there an
alternative method rather than the one in the TESS examples or a
single collector field model?

Best Regards,

Tufan AKBA