[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Error reading buifile



Mattia,
  Killing yourself is certainly a permanent solution to the problem. Before you do, however, make sure that the schedule you are deleting isn't used in any of the zones or gains. I am guessing that the reason TRNBuild won't open or process the *.b17 file is that a schedule is implemented but not defined. Open the *.b17 in a text editor and search on UTILIZZO. In addition to deleting the definition of the schedule, you also have to delete all uses of the schedule.
Best,
 David

On 7/23/2012 09:30, MATTIA ANDREA RIO wrote:
hi guys, before than i try to kill myself, anyone could tell me how i can do to solve this problem?

I'm trying to modify the built file using one text editing program, but even if i delete the output: schedule UTILIZZO, simulation studio show me the same error! help me!


Thanks!!!

----------------------------------------------------------------
This message was sent using IMP, the Internet Messaging Program.



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com