[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] cold bridge



Dear Karol,

You can't modify geometry in trnbuild if detailed radiation model are selected, that's why coldbridges can't be modified.
You can integrate coldbridges in wall u-value definition :
  • Uvalue = (Uwall*Area + Coldbridge_1 x L_1 + Coldbridge_2 x L_2 + ... +  Coldbridge_i x L_i)/Area

For windows, you can do the same and include coldbridges in Uw value (modify c-value)

Best regards

www.itf.biz
www.itf.biz
Adrien JEZEQUEL
Simulations Thermiques Dynamiques
ITF
62, Rue du Bolliet
73230 St Alban Leysse
FRANCE
Phone :
Fax :
Mail:
+33(0) 479 750 029
+33(0) 479 852 122
a.jezequel@itf.biz ou aj@itf.biz
Afin de contribuer au respect de l'environnement, merci de n'imprimer cet e-mail que si nécessaire
Please, consider our environmental responsability before printing this email
Le 04/07/2012 11:34, Karol Bandurski a écrit :
Dear All,

Could somebody explain me how to model cold bridge effect?

Building, which I model, have balcony. So, I go to zone which is directly
connect with balcony, highlight  exterior wall where balcony hangs and what
data should I put?

There is resistance of connection wall-balcony or whole wall taking into
account this connection?
The same question is to other parameters?

After I accept cold bridge windows I cannot set cold bridge dimension
because it is blocked (gray)... Why?

Thank in advance for your time!!!

Regards,

------------------------------------------------
Karol Bandurski MSc.
Institute of Environmental Engineering
Poznan University of Technology
www.ee.put.poznan.pl
www.put.poznan.pl

 