Re: [TRNSYS-users] void as inter-zonal wall



If you are using 3d sketchup plugin, then look to the virtual partition option. This creates (when imported into trnsbuild x2 airnodes for one zone, in essance 2 zones. bear in mind that there is no air exchange between the two zones...for this you need to use a "coupling". It is basically like two zones, but for the radiation exchanges.

On 2 July 2012 14:34, Eva gklezakou <gklezakoue@gmail.com> wrote:
Dear Sirs,

I model a multi-zone building and there are two adjacent zones which do not have inter-zonal wall between them, because of the geometry and the orientation I decided not to model them as one zone. How can I assign the lack of inter-zonal wall, is it enough if I set an air layer as the only wall's material? Do I have to assign any other parameter in order to be more accurate?
Thank you.

Regards,
Eva

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users