[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] weird Qcool



Dear all,

I make a simulation. The cooling set temperature is 24*Summer schedule (2162 h to 6552 h), The heating set temperature is 21*Winter schedule (the rest hours). After running, however, it appears WEIRD phenomenon. Please see the ATTACHED Energy_zone.BAL file. During the winter period, there are Qcools and Qcool is very large up to 47000 kJ. And then it results in wrong BAL_ENERG, it is not 0.

Please give me some advices and solutions to that!

Many thanks in advance!

Br.

wang 


2012/6/11 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. Re: TRNSYS-users Digest, Vol 90, Issue 21
     (jose.gonzalez@imdea.org)
  2. AutoReply: TRNSYS-users Digest, Vol 90, Issue 21
     (kelelo1@kelelo.com)
  3. type666 (Andr?s Montero)
  4. Type 673 heating problem (Santeri Siren)


---------- 已转发邮件 ----------
From: <jose.gonzalez@imdea.org>
To: trnsys-users@cae.wisc.edu
Cc: 
Date: Mon, 11 Jun 2012 16:07:28 +0200 (CEST)
Subject: Re: [TRNSYS-users] TRNSYS-users Digest, Vol 90, Issue 21
I am out of the office from Monday, June 11 to Friday, June 15 and unable to respond at this time.

For any urgent matters, please contact Dr. Manuel Romero (manuel.romero_at_imdea.org).

Thank you for your understanding.

Best regards,

José Gonzalez-Aguilar



---------- 已转发邮件 ----------
From: kelelo1@kelelo.com
To: trnsys-users@cae.wisc.edu
Cc: 
Date: Mon, 11 Jun 2012 14:10:47 GMT
Subject: [TRNSYS-users] AutoReply: TRNSYS-users Digest, Vol 90, Issue 21

I will be out of the office from June 8 - 23 on a backpacking trip with my son and his Venture Crew at Philmont Scout Ranch in New Mexico. I will not have access to email or phone service while I am gone, but I will reply to your message as soon as possible after I return to the office on Monday, June 25th.

Thank you for your patience,
Mark Thornbloom




---------- 已转发邮件 ----------
From: "Andrés Montero" <andresmonteroi@gmail.com>
To: trnsys-users@cae.wisc.edu
Cc: 
Date: Mon, 11 Jun 2012 16:57:30 +0200
Subject: [TRNSYS-users] type666
Dear Trnsys users,

In order to simulate a water-cooled chiller, first I need to create the 2 external files for this component. 
I'm trying to find some catalogues with information of a 40 to 45 kW water-cooled chiller but the web pages I run into it, ask me to register, but I'm still waiting the username and pasword. Does anyone has a catalgoue with this type of info regarding this cooling capacity machine?

Best regards,

Andrés

--
Andrés Montero I.



---------- 已转发邮件 ----------
From: Santeri Siren <santeri.siren1@gmail.com>
To: "trnsys käyttäjät" <trnsys-users@cae.wisc.edu>
Cc: 
Date: Mon, 11 Jun 2012 19:56:40 +0300
Subject: [TRNSYS-users] Type 673 heating problem
Dear all,

I cant make type673 heating mode to work. Cooling mode works just fine but when I change the cooling control signal to 0 and heating control signal to 1 it doesnt work anymore. When the heating mode is used nothing happens. Does anyone know why?

Best regards,
Santeri Siren

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users


Attachment: Energy_zone.BAL
Description: Binary data