Wang,
The *.bui file contains all of the building information. It sometimes has the file extension *.b16 or *.b17. I would do a search on your computer and find the file. If such a file does not exist then there is a problem with the building that you are specifying in the wizard. You need to solve that problem and make sure that a *.bui *.b16 or *.b17 file is being created. Only after you are sure that you have such a file can you verify that the Trnsys Studio path pointing to that file is correct.
Regards,
David
On 6/6/2012 02:00, 王洋 wrote:
Hi Mayank,
Many thanks for your quick reply!
However, I can't find the *.bui file the last attached figure shows the path of the file, i.e. the *.bui file can't be created perhaps!
Additionally, it shows the attached BUG when I open TRNBuild directly or select "Edit Building" for Type 56 in TRNSYS Studio.
Do you and other experts have some solutions or advices for that?
Many thanks in advance!
Br.
wang
---------- Forwarded message ----------
From: 王洋 <wanghongyang1767@gmail.com>
Date: 2012/6/5
Subject: Re: TRNSYS Wizard Problem
To: mayank bhatnagar <mayank.23aug@gmail.com>
Cc: trnsys-users@cae.wisc.edu
2012/6/5 mayank bhatnagar <mayank.23aug@gmail.com>
Hi Wang,
This error occur when you do not specify the building file (.bui) made in TRNBuild. there is type 56 or other which define building in model. Go to that component then files tab and then browse your building file. I think it resolve your problem.
Regards,
Mayank Bhatnagar
Energy Analyst
Environmental design solutions,
India.
On Tue, Jun 5, 2012 at 4:08 PM, <trnsys-users-request@cae.wisc.edu> wrote:
Send TRNSYS-users mailing list submissions to
trnsys-users@cae.wisc.edu
To subscribe or unsubscribe via the World Wide Web, visit
https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
trnsys-users-request@cae.wisc.edu
You can reach the person managing the list at
trnsys-users-owner@cae.wisc.edu
When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."
Today's Topics:
1. TRNSYS Wizard Problem (??)
---------- Forwarded message ----------
From: 王洋 <wanghongyang1767@gmail.com>
To: trnsys-users@cae.wisc.edu
Cc:
Date: Tue, 5 Jun 2012 12:37:59 +0200
Subject: [TRNSYS-users] TRNSYS Wizard Problem
Dear all,
I made the simulation using TRNSYS Wizard, however, after that I got a TRNSYS Bug. Please see the attached figure which is the bug I met. (English meaning:*.bui file contains an invalid path )
Do you experts have some solutions or advices for that?
Once I use the TRNSYS Wizard to produce other any new program, it appears this bug all the time. If I can not deal with it, I will not continue to work using TRNSYS.
Many thanks in advance!
Br.
wang
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://mailman.cae.wisc.edu/listinfo/trnsys-users
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com
Attachment:
not find library.bmp