[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] UWin for horizontal windows



Dear users

 

I try to understand the discrepancy of UWin variations between an horizontal window (slope=0 in Window Type Manager, blue line in attached chart) and a vertical one (slope=90 in Window Type Manager, pink line in attached chart).

I guess that it is mainly due to the convective heat exchange coefficient between the individual glazings. As specified in §5.4.2.4 of user manual, the convective transfer is indeed calculated from the surface temperature difference (red line in attached chart) and the slope of the window.

My questions now.

1/ Could anyone confirm that my guess is actually correct?

2/ What about the Nu computation in case of cos(Beta)=0 in Eq. 5.4.2-13?

3/ Uw values of manufactured windows should be quite different depending on their intended orientation. Are the Uw values of roof windows specified with increased convection effects?

 

Thanks a lot for your help on that !

--

Antoine Gautier
Solam
en SAS
+33 6 58 24 02 60

antoine.gautier@solamen.fr

 

Attachment: Capture.PNG
Description: PNG image